Prescribed targets for titration of vasopressors in septic shock: a retrospective cohort study.
Аннотация
BACKGROUND
Without robust clinical evidence to guide titration of vasopressors in septic shock, it is unclear how dosing of these potent medications occurs. We sought to measure the proportion of vasopressor prescriptions for septic shock that were missing explicit targets and to describe the targets that we identified.
METHODS
We conducted a multicentre, retrospective cohort study involving 9 intensive care units (ICUs) located at 3 academic hospitals in Canada and Australia. We reviewed charts of consecutive patients aged 18 years or older who were admitted to the ICU for a presumptive diagnosis of sepsis. Other inclusion criteria were hypotension (systolic arterial pressure ≤ 90 mm Hg or mean arterial pressure [MAP] ≤ 65 mm Hg) and continuous infusion of vasopressors for at least 1 hour within the initial 48 hours of ICU stay, the period of observation for this study.
RESULTS
We included data from 369 patient charts. At least 1 target was specified in 99% of charts. The most common targets were MAP measurements (73%). The median initial MAP target was 65 (range 55-90) mm Hg. In multivariable regression models, hospital site and older age of the patient, but not comorbidities of the patient, were associated with MAP targets. In 40% of patients, the treating team modified the initial target at least once.
INTERPRETATION: This study suggests that an explicit blood pressure target accompanies nearly every vasopressor prescription and that patient characteristics have little influence on its value. Identification of a titration strategy that will maximize benefit and minimize harm constitutes a research priority.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.