Аннотация

OBJECTIVES

To evaluate the placental function by monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in patients with placenta previa.

METHODS

A total of 62 patients with placenta accreta spectrum (PAS) disorders and 11 patients with normal placentas were retrospectively enrolled, who underwent conventional diffusion-weighted imaging (DWI), intravoxel incoherent motion (IVIM), and diffusion kurtosis imaging (DKI). The apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, mean kurtosis (MK), and diffusion coefficient (MD) from DKI, and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured and compared from the volumetric analysis.

RESULTS

Comparisons between patients with PAS disorders and patients with normal placentas demonstrated that MD mean, D mean, and D* mean values in patients with PAS disorders were significantly higher than those in patients with normal placentas (p < 0.05). Comparisons between patients with accreta, increta, and percreta, and patients with normal placentas showed that the D mean was significantly higher in patients with placenta increta and percreta than in patients with normal placentas (p < 0.05).

CONCLUSION

The accreta lesions in PAS disorders had deceased cellularity and increased blood movement. The alteration of placental cellularity was more prominent in placenta increta and percreta.

Для цитирования: Lu Tao, Wang Yishuang, Deng Yan, Wu Chengqian, Li Xiangqi, Wang Guotai. Diffusion and perfusion MRI parameters in the evaluation of placenta accreta spectrum disorders in patients with placenta previa.. Magma (New York, N.Y.). 2022. DOI: 10.1007/s10334-022-01023-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.