MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiochem.2021.05.004

Медицинская библиотека · Clinical biochemistry · 2021

Urine toxicology screening by liquid chromatography time-of-flight mass spectrometry in a quaternary hospital setting.

Pope Jeffrey D, Black Marion J, Drummer Olaf H, Schneider Hans G

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Validation of a non-targeted method for urine drug screening (UDS) by liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF), and comparison to an established GC-MS method in a hospital setting.

METHODS

217 UDS specimens sent to a quaternary hospital pathology department, were analysed by a CEDIA® immunoassay screen (six drug panels; amphetamines, barbiturates, benzodiazepines, cocaine metabolites, cannabinoids and opiates) on an Abbott Architect instrument. Specimens were subsequently analysed by an established non-targeted qualitative GC-MS method and results compared with a general unknown screening method by LC-QTOF that was under evaluation as a replacement method.

RESULTS

42 selected drugs were evaluated; limits of identification ranged from 2 to 100 µg/L and most drugs (n = 39) were stabile for 24 h after preparation. Matrix effects greater than 25% were observed in seven of the selected drugs. 87% of the specimens tested positive to 1 or more drug panels in a CEDIA® screen. A total of 537 positive drug findings were identified by GC-MS compared to 1,267 positive findings by LC-QTOF. On average, each GC-MS screen identified 2.5 ± 1.8 drugs and the LC-QTOF screen identified 5.8 ± 3.2 drugs. No drugs were identified in 11.3% of the GC-MS screens, whereas drugs were detected in 99% of these by the LC-QTOF. In almost all instances, the LC-QTOF screen could provide mass spectrometric confirmatory results of positive immunoassay screens and was able to identify a wider range of additional drugs and drug metabolites.

CONCLUSIONS

The described general unknown screening (non-targeted, qualitative) LC-QTOF method can detect a larger range of drugs encountered in a hospital setting. The method has been shown to be suitable for comprehensive toxicology screening in a clinical toxicology laboratory.

Для цитирования: Pope Jeffrey D, Black Marion J, Drummer Olaf H, Schneider Hans G. Urine toxicology screening by liquid chromatography time-of-flight mass spectrometry in a quaternary hospital setting.. Clinical biochemistry. 2021. DOI: 10.1016/j.clinbiochem.2021.05.004.