MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2024.10.024

Медицинская библиотека · JACC. Cardiovascular interventions · 2024

Coronary Physiological Indexes to Evaluate Myocardial Ischemia in Patients With Aortic Stenosis Undergoing Valve Replacement.

Minten Lennert, McCutcheon Keir, Vanhaverbeke Maarten, Wouters Laurine, Bézy Stéphanie, Lesizza Pierluigi, Jentjens Sander, Frederiks Pascal, Bringmans Tijs, Voigt Jens-Uwe, Adriaenssens Tom, Desmet Walter, Sinnaeve Peter, Jacobs Steven, Verbrugghe Peter, Meuris Bart, Janssens Stefan, Fearon William F, Bennett Johan, Dubois Christophe

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The evaluation of myocardial ischemia in patients with aortic valve stenosis (AS) with concomitant coronary artery disease (CAD) and possible microvascular dysfunction (MVD) is challenging because fractional flow reserve (FFR) and the resting full-cycle ratio (RFR) have not been validated in this clinical setting.

OBJECTIVES

The aims of this study in patients with AS and CAD were: 1) to describe the relationship between hyperemic and resting indexes; 2) to investigate the acute and long-term effects of aortic valve replacement (AVR) on epicardial indexes and microvascular function; 3) to assess the impact of these changes on clinical decision making; and 4) to determine FFR/RFR ischemia cutoff points in AS.

METHODS

In this prospective multicentric study, we performed serial measurements of FFR and RFR and evaluated MVD by means of coronary flow reserve, the index of microvascular resistance, and microvascular resistance reserve in patients with severe AS and intermediate to severe CAD before and 6 months after AVR. Patients underwent myocardial perfusion single-photon emission computed tomography before AVR.

RESULTS

In total, 146 coronary lesions in 116 patients were included. Before AVR, we observed high FFR/RFR discordance according to standard cutoff values (FFR negative [>0.80]/RFR positive [≤0.89] in 42.3% [68/137] of these lesions). Acutely after AVR, FFR decreased significantly (-0.0120 ± 0.0192; P = 0.0045), whereas RFR remained stable (0.0140 ± 0.0673; P = 0.3089). Six months after AVR, FFR decreased (-0.0279 ± 0.0368), whereas RFR increased significantly (+0.0410 ± 0.0487) (P < 0.0001 for both), resulting in 21.5% (21/98) and 39.8% (39/98) of lesions crossing traditional FFR and RFR cutoff lines, respectively. Left ventricular mass decreased significantly (153.68 ± 44.22 g before vs 134.66 ± 37.26 g after; P < 0.0001). MVD was frequently observed at baseline (32.1% abnormal index of microvascular resistance and 68.6% abnormal microvascular resistance reserve) with all microvascular parameters improving after AVR. The most accurate cutoffs to predict ischemia were FFR ≤0.83 and RFR ≤0.85 with comparable accuracy (75%-80%).

CONCLUSIONS

In patients with severe AS and CAD, FFR ≤0.83 and RFR ≤0.85 appear to predict myocardial ischemia more accurately. Six months after AVR, FFR decreases, whereas RFR increases significantly with a simultaneous decrease of left ventricular mass and an improvement of microvascular function.

Для цитирования: Minten Lennert, McCutcheon Keir, Vanhaverbeke Maarten, Wouters Laurine, Bézy Stéphanie, Lesizza Pierluigi, Jentjens Sander, Frederiks Pascal, Bringmans Tijs, Voigt Jens-Uwe, Adriaenssens Tom, Desmet Walter, Sinnaeve Peter, Jacobs Steven, Verbrugghe Peter, Meuris Bart, Janssens Stefan, Fearon William F, Bennett Johan, Dubois Christophe. Coronary Physiological Indexes to Evaluate Myocardial Ischemia in Patients With Aortic Stenosis Undergoing Valve Replacement.. JACC. Cardiovascular interventions. 2024. DOI: 10.1016/j.jcin.2024.10.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.