Management of subacute and delayed right ventricular perforation with a pacing or an implantable cardioverter-defibrillator lead.

Laborderie Julien, Barandon Laurent, Ploux Sylvain, Deplagne Antoine, Mokrani Bilel, Reuter Sylvain, Le Gal François, Jais Pierre, Haissaguerre Michel, Clementy Jacques, Bordachar Pierre

СтатьяПеревод в очереди

Аннотация

The development of small-diameter active fixation pacing and implantable cardioverter-defibrillator leads may be associated with increased risk for delayed right ventricular perforation. The management of this unforeseen complication has been poorly described. Eleven successive patients referred for right ventricular subacute or delayed perforation (no evidence of lead perforation at the time of the procedure, perforation of the right ventricle diagnosed > or =5 days after implantation) were reviewed. The perforation was related to a pacing (n = 7) or an implantable cardioverter-defibrillator (n = 4) lead. The main symptoms were major dyspnea with pericardial effusion requiring emergency pericardial drainage (n = 3), inappropriate implantable cardioverter-defibrillator shock (n = 1), syncope (n = 2), abdominal pain (n = 1), mammary hematoma (n = 1), diaphragm stimulation (n = 1), and chest pain (n = 1). One patient was strictly asymptomatic. Signs of lead dysfunction were observed in all 11 patients. The diagnosis of lead perforation was confirmed by chest x-ray, echocardiography, or computed tomography. Surgery was directly performed in 1 patient with suspicion of digestive perforation. In the remaining 10 patients, the leads were removed by simple traction under fluoroscopic guidance in the operating room, with surgical backup support. The need for close monitoring was highlighted by the occurrence in 1 patient of tamponade requiring percutaneous pericardiocentesis and urgent surgical revision. The postoperative course of these patients was unremarkable. In conclusion, subacute ventricular perforation is a rare but potentially life threatening complication of lead implantation. In most patients, the leads can safely be removed under fluoroscopic guidance, with surgical backup support and close monitoring.

Для цитирования: Laborderie Julien, Barandon Laurent, Ploux Sylvain, Deplagne Antoine, Mokrani Bilel, Reuter Sylvain, Le Gal François, Jais Pierre, Haissaguerre Michel, Clementy Jacques, Bordachar Pierre. Management of subacute and delayed right ventricular perforation with a pacing or an implantable cardioverter-defibrillator lead.. The American journal of cardiology. 2008. DOI: 10.1016/j.amjcard.2008.07.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.