MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/children13020262

Медицинская библиотека · Children (Basel, Switzerland) · 2026

The Effects of Vasoactive Medications on Mean Circulatory Filling Pressure, Venous Resistance, Systemic Vascular Resistance, Cardiac Index, and Oxygen Extraction After Pediatric Heart Transplant: Leveraging High-Fidelity Physiologic Data.

Behrend Julia, Hoffman George, Kheir John N, Sourour Wesam, Joong Anna, Loomba Rohit S

СтатьяПеревод в очереди

Аннотация

Background

The physiologic effects of vasoactive medications on the venous circulation remain incompletely understood. Contemporary bedside management often emphasizes the arterial circulation, whereas Guytonian physiology emphasizes the venous circulation and mean circulatory filling pressure in determining steady-state cardiac output. The primary aim of this study was to characterize the effect of vasoactive medications on mean circulatory filling pressure and venous resistance.

Methods

Demographic data and vasoactive data were collected from the electronic health record and collated with high-fidelity physiologic monitoring data. Mean circulatory filling pressure and venous resistance were calculated using clinically validated equations and then were modeled using a random forest regression incorporating postoperative time and infusion doses of epinephrine, norepinephrine, milrinone, vasopressin, phenylephrine, calcium, sodium nitroprusside, and nicardipine. Similar models were constructed for indexed systemic vascular resistance, cardiac index, cerebral oxygen extraction, and renal oxygen extraction.

Results

Data from a total of 57 unique patients comprising 9,654,239 data points were analyzed. The model explained 57% of the variance in mean circulatory filling pressure and 59% of the variance in venous resistance. Vasopressin and norepinephrine were the most influential for mean circulatory filling pressure and venous resistance.

Conclusions

Vasoactive medications appear to modulate venous tone and impact mean circulatory filling pressure and venous resistance. High-fidelity physiologic data allow for characterizing these effects and guide titration of vasoactive medications at the bedside.

Для цитирования: Behrend Julia, Hoffman George, Kheir John N, Sourour Wesam, Joong Anna, Loomba Rohit S. The Effects of Vasoactive Medications on Mean Circulatory Filling Pressure, Venous Resistance, Systemic Vascular Resistance, Cardiac Index, and Oxygen Extraction After Pediatric Heart Transplant: Leveraging High-Fidelity Physiologic Data.. Children (Basel, Switzerland). 2026. DOI: 10.3390/children13020262.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.