m+Medelevator.RU
← Поиск публикаций
International journal for numerical methods in biomedical engineering · 2025

Hemodynamic Evaluation of Intra-Aortic Dual-Balloon Pump Based on Fluid-Structure Interaction.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ma Hongchao, Wang Yuhan, Gao Bin, Li Shu, Song Zhiming, Chang Yu, Zhang Ran

Аннотация

The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP. Three-dimensional finite element models were constructed for the aorta, IABP, and IADBP, followed by numerical simulation using the fluid-structure coupling (FSI) method. Three simulations were conducted: Heart failure patients without assistive devices (Case A), those with IABP (Case B), and those with IADBP (Case C). The study assessed the IADBP's hemodynamic effects by measuring aortic branch blood flow, left ventricular afterload, aortic wall stress, and wall shear stress. IADBP outperformed IABP in enhancing blood flow to the coronary arteries, upper limbs, and brain vessels (left and right coronary arteries: 0.88 vs. 1.27, 1.27 vs. 1.99 mL/beat; brachiocephalic artery, left common carotid artery, and left subclavian artery: 6.08 vs. 12.39, 2.48 vs. 4.97, 2.31 vs. 5.08 mL/beat). IADBP also demonstrated superior performance in counterpulsation pressure and left ventricular ejection (counterpulsation phase: 97.41 mmHg vs. 110.03 mmHg; ventricular unloading phase: 72.21 mmHg vs. 66.46 mmHg). The use of IADBP elevates stress on the aortic wall and wall shear stress, potentially affecting vascular health. IADBP effectively addresses upper limb and cerebral hypoperfusion issues associated with IABP, demonstrating superior performance in enhancing counterpulsation pressure and left ventricular ejection. Despite potential vascular biomechanical effects, IADBP provide a promising clinical treatment option. Further studies are needed to refine IADBP 's design and evaluate its long-term clinical efficacy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты