MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721211005320

Медицинская библиотека · European journal of ophthalmology · 2021

Anterior approach levator plication for congenital ptosis, absorpable versus non absorpable sutures.

Salamah Moustafa, Eid Ashraf Mahrous, Albialy Hani, Sharaf El Deen Sherif

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the efficacy of two different suture types in levator plication for correction of congenital ptosis.

SUBJECTS AND

METHODS

Prospective comparative interventional randomized study involving 42 eyes of 42 patients aged more than 6 years with congenital ptosis and good levator action. The exclusion criteria were as follows: bilateral ptosis, history of previous surgery, fair or poor levator action, and associated other ocular diseases. Patients were randomized into group A, in which double-armed 5/0 polyester Ethibond were used, and group B, in which double-armed 5/0 Coated Vicryl® (polyglactin 910) suture material we used. Outcomes including eyelid height and stability of eyelid height over time were compared with follow-up data. The MRD was 4.05 ± 0.36 mm and 3.95 ± 0.34 after 1 week for both groups A and B, respectively. At the end of study follow up period (24 weeks), the MRD was 3.60 ± 0.42 mm in group A, and 2.52 ± 0.85 mm in group B.

CONCLUSION

No difference in eyelid height between two groups in early postoperative period, but the postoperative eyelid height was more stable over time in the 5/0 polyester Ethibond group (group A) than in the 5/0 Coated Vicryl® (polyglactin 910) group (group B).

Для цитирования: Salamah Moustafa, Eid Ashraf Mahrous, Albialy Hani, Sharaf El Deen Sherif. Anterior approach levator plication for congenital ptosis, absorpable versus non absorpable sutures.. European journal of ophthalmology. 2021. DOI: 10.1177/11206721211005320.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.