m+Medelevator.RU
← Поиск публикаций
The Journal of arthroplasty · 2016

Does High Hip Center Decrease Range of Motion in Total Hip Arthroplasty? A Computer Simulation Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Komiyama Keisuke, Nakashima Yasuharu, Hirata Masanobu, Hara Daisuke, Kohno Yusuke, Iwamoto Yukihide

Аннотация

BACKGROUND: High placement of a cementless acetabular cup is often required to have sufficient bone coverage in hip dysplasia. We examined whether a high hip center decreases the postoperative range of motion (ROM) in total hip arthroplasty.

METHODS: Using a computer software, ROM and bone coverage were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. The cup was placed at the anatomic hip center and moved vertically in 5-mm increments. Vertical center of rotation (V-COR) was defined as the distance from the head center to the interteardrop line. The required ROM was defined as flexion  ≥110°, internal rotation (IR) at 90° flexion ≥30°, extension ≥30°, and external rotation ≥30°. We determined the V-COR to satisfy the required ROM and cup center-edge angle (Cup-CE) ≥0°.

RESULTS: Only 40.6% of the patients satisfied Cup-CE ≥0° at the anatomic hip center. Bone coverage increased with the peak at 30, 35 mm of V-COR (90.6% satisfied Cup-CE ≥0°) and decreased at ≥40 mm. Higher V-COR resulted in lower range of flexion and IR, but increased the range of extension and external rotation. The cutoff value from the receiver-operating characteristic curve for both flexion and IR was a V-COR of 35 mm.

CONCLUSION: The higher hip center gained more bone coverage but decreased the range of hip flexion and IR. Acceptable V-COR in hip dysplasia was around 35 mm, about 20 mm above the true hip center, in terms of ROM.