MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00167-015-3550-7

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2015

Quantitative analysis of the patella following the harvest of a quadriceps tendon autograft with a bone block.

Ferrer Gerald A, Miller R Matthew, Murawski Christopher D, Tashman Scott, Irrgang James J, Musahl Volker, Fu Freddie H, Debski Richard E

СтатьяПеревод в очереди

Аннотация

PURPOSE: The objective of this study was to determine parameters associated with patellar fracture after quadriceps tendon autograft harvest.

METHODS

Thirteen non-fractured and five fractured patella surface models were created based on patient data obtained from a prospective randomized clinical trial in order to assess geometric parameters and bending stress. Measurements that describe the bone block harvest site geometry were used to calculate three normalized parameters. The relative depth parameter describes the thickness of the bone block harvest site with respect to the thickness of the patella at the harvest site. The asymmetry parameter defines the medial-lateral location of the bone bock harvest site. The normalized bending stress parameter assesses the bending stress experienced by the remaining bone beneath the bone block harvest site.

RESULTS

The relative depth of the bone block harvest site in the non-fractured patellae was 27 ± 12 % and for the fractured patellae was 42 ± 14 % (p < 0.05). With a value <1 indicating a more lateral location of the harvest site, asymmetry for the non-fractured group was 1.0 ± 0.5 and 0.7 ± 0.4 for the fractured group (n.s.). The maximum bending stress experienced by the non-fractured patellae was (1.8 × 10(-3) ± 1.3 × 10(-3)) mm(-3) × M and for the fractured patellae was over three times greater (6.3 × 10(-3) ± 3.7 × 10(-3)) mm(-3) × M (p < 0.05).

CONCLUSION

Based on the non-uniform geometry of the patella, an emphasis should be made on harvesting a standard percentage of patella thickness rather than a fixed depth. In order to minimize the incidence of a patellar fracture, bone blocks should not be taken laterally and should not exceed 30 % of the total patella thickness at the harvest site.

Для цитирования: Ferrer Gerald A, Miller R Matthew, Murawski Christopher D, Tashman Scott, Irrgang James J, Musahl Volker, Fu Freddie H, Debski Richard E. Quantitative analysis of the patella following the harvest of a quadriceps tendon autograft with a bone block.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2015. DOI: 10.1007/s00167-015-3550-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.