Hemostatic Effects of Tranexamic Acid in Cesarean Delivery: An Ancillary Study of the TRAAP2 Study.
Аннотация
BACKGROUND
Fibrinolysis activation during delivery contributes to postpartum hemorrhage (PPH). Clot lysis time studied with the global fibrinolytic capacity device (GFC/LT) is a functional test which rapidly assesses fibrinolytic profile. Tranexamic acid (TXA) is an efficient antifibrinolytic therapy.
METHODS
We prospectively studied fibrinolysis and coagulation in 33 women included in the TRAAP2 trial, which aimed to assess the impact of TXA in preventing PPH following a cesarean delivery. TXA or placebo was randomly administered after childbirth as part of the TRAAP2 trial's protocol. Fibrinolytic (GFC/LT, plasma concentration of fibrinolysis activators and inhibitors) and hemostatic parameters were assayed at three sample times (TREF [T-reference] after anesthesia, T15 and T120minutes after TXA, or placebo administration).
RESULTS
All cesarean deliveries were elective. In the placebo group, the clot lysis time assessed with GFC/LT significantly decreased between TREF and T120, indicating an activated fibrinolysis (44 [interquartile range, IQR: 40-48] vs. 34 [IQR: 30-36] minutes, p<0.001). In both TXA and placebo groups, significant fluctuations of the plasmatic concentrations of fibrinolytic mediators were noticed over time, suggesting fibrinolysis activation. Clot lysis time measured by GFC/LT was significantly increased in women of the TXA group as compared with those in the placebo group at T15 (120 [120-120] vs. 36 [34-41] minutes, p<0.001) and T120minutes (113 [99-120] vs. 34 [30-36] minutes, p<0.001) after drug administration, indicating a decreased in fibrinolysis in those women.
CONCLUSION
GFC/LT evidenced fibrinolysis activation during cesarean delivery, linked to a decrease in fibrinolytic inhibitors. GFC/LT revealed a significant antifibrinolytic effect of TXA compared with placebo.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.