Immunohistochemical characteristics of local sites that trigger atrial arrhythmias in response to high-frequency stimulation.

Kim Min-Young, Nesbitt James, Koutsoftidis Simos, Brook Joseph, Pitcher David S, Cantwell Chris D, Handa Balvinder, Jenkins Catherine, Houston Charles, Rothery Stephen, Jothidasan Anand, Perkins Justin, Bristow Poppy, Linton Nick W F, Drakakis Emm, Peters Nicholas S, Chowdhury Rasheda A, Kanagaratnam Prapa, Ng Fu Siong

СтатьяПеревод в очереди

Аннотация

AIMS: The response to high frequency stimulation (HFS) is used to locate putative sites of ganglionated plexuses (GPs), which are implicated in triggering atrial fibrillation (AF). To identify topological and immunohistochemical characteristics of presumed GP sites functionally identified by HFS.

METHODS AND

RESULTS

Sixty-three atrial sites were tested with HFS in four Langendorff-perfused porcine hearts. A 3.5 mm tip quadripolar ablation catheter was used to stimulate and deliver HFS to the left and right atrial epicardium, within the local atrial refractory period. Tissue samples from sites triggering atrial ectopy/AF (ET) sites and non-ET sites were stained with choline acetyltransferase (ChAT) and tyrosine hydroxylase (TH), for quantification of parasympathetic and sympathetic nerves, respectively. The average cross-sectional area (CSA) of nerves was also calculated. Histomorphometry of six ET sites (9.5%) identified by HFS evoking at least a single atrial ectopic was compared with non-ET sites. All ET sites contained ChAT-immunoreactive (ChAT-IR) and/or TH-immunoreactive nerves (TH-IR). Nerve density was greater in ET sites compared to non-ET sites (nerves/cm2: 162.3 ± 110.9 vs. 69.65 ± 72.48; P = 0.047). Overall, TH-IR nerves had a larger CSA than ChAT-IR nerves (µm2: 11 196 ± 35 141 vs. 2070 ± 5841; P < 0.0001), but in ET sites, TH-IR nerves were smaller than in non-ET sites (µm2: 6021 ± 14 586 vs. 25 254 ± 61 499; P < 0.001).

CONCLUSIONS

ET sites identified by HFS contained a higher density of smaller nerves than non-ET sites. The majority of these nerves were within the atrial myocardium. This has important clinical implications for devising an effective therapeutic strategy for targeting autonomic triggers of AF.

Для цитирования: Kim Min-Young, Nesbitt James, Koutsoftidis Simos, Brook Joseph, Pitcher David S, Cantwell Chris D, Handa Balvinder, Jenkins Catherine, Houston Charles, Rothery Stephen, Jothidasan Anand, Perkins Justin, Bristow Poppy, Linton Nick W F, Drakakis Emm, Peters Nicholas S, Chowdhury Rasheda A, Kanagaratnam Prapa, Ng Fu Siong. Immunohistochemical characteristics of local sites that trigger atrial arrhythmias in response to high-frequency stimulation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2023. DOI: 10.1093/europace/euac176.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.