DOI 10.1097/lgt.0000000000000467
Impact of the Sampling Site in the Result of Wet Mount Microscopy.
Аннотация
OBJECTIVES
Wet mount microscopy (WMM) is an ancillary test in the diagnosis of vulvovaginitis. However, there are little data about the impact of the sampling site. Our main objective was to determine the agreement between samples collected from different vaginal sites.
MATERIALS AND
METHODS
Five vaginal samples (one from each of the fornices and one from the lower third) were collected from 50 consecutive women and evaluated using phase-contrast WMM, including the following: lactobacillary grade, presence of other bacteria, clue cells, inflammation, and atrophy. Global percentage of agreement, κ index [poor (<0), slight (0.01-0.20), fair (0.21-0.40), moderate (0.41-0.60), substantial (0.61-0.80), and almost perfect (0.81-1)], sensitivity and negative predictive value were calculated.
RESULTS
Global percentage of agreement was high for all individual parameters (>75%), but low for the final diagnosis (57%). Agreement rate was substantial or almost perfect for the evaluation of normal versus abnormal flora, substantial for the presence of absence of bacteria other than lactobacilli and for the presence of clue cells, and moderate to almost perfect for the presence of dysbiosis and cytolysis. Agreement rates were worse for inflammation, atrophy, and the presence of Candida. The lower third of the vagina had the highest sensitivity for Candida (0.6, 95% CI = 0.41-0.86) and bacterial vaginosis (0.92, 95% CI = 0.73-1.00), whereas the anterior fornix performed better for cytolytic vaginosis (0.75, 95% CI = 0.43-0.93).
CONCLUSIONS
There is some variation in the results according to the sampling site, which may be overcome by collecting 2 samples (anterior fornix and lower third of the vagina).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.