MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics16111587

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2026

Doppler Ultrasound Findings in Filler-Related Facial Vascular Adverse Events: An International Multicenter Study.

Sigrist Rosa M S, Gonzalez Claudia, Schelke Leonie, Wortsman Ximena, Desyatnikova Stella, Cavallieri Fernanda A, Chammas Maria Cristina

СтатьяПеревод в очереди

Аннотация

Background

Vascular adverse events (VAEs) related to facial filler injections are rare but potentially severe complications. Doppler ultrasound has emerged as an adjunct imaging tool for evaluating vascular compromise; however, Doppler findings in facial VAEs remain insufficiently characterized.

Objectives

To characterize Doppler ultrasound findings associated with filler-related facial VAEs and to assess whether Doppler patterns differ according to prior hyaluronidase administration.

Methods

This international multicenter retrospective observational study included 100 patients with clinically diagnosed facial VAEs following filler injections between May 2022 and April 2025. Doppler ultrasound findings were analyzed, including absent flow in perforators and major arteries, compensatory flow, abnormal waveforms, increased peak systolic velocity (PSV), and absence of Doppler abnormalities. Patients were categorized according to hyaluronidase administration prior to ultrasound evaluation. Descriptive statistics and comparative analyses were performed.

Results

One hundred patients (median age, 38 years; IQR: 30-50; 88 women) were evaluated. The most frequent Doppler ultrasound findings were absent flow in perforators (42%) and major arteries (35%), followed by compensatory flow (26%), string sign (18%), flow diversion (16%), and increased peak systolic velocity (16%). No Doppler abnormalities were observed in 12% of cases, while tardus-parvus (9%) and staccato waveform (8%) were less frequent. Doppler ultrasound findings did not differ significantly between patients who received hyaluronidase before imaging and those who did not (all p > 0.05). The dose of hyaluronidase varied substantially. Livedo reticularis, blanching, and pain were the most common clinical findings. Central facial arterial territories, particularly the perioral, nasolabial fold, nasal, and glabellar regions, were most commonly involved.

Conclusions

Filler-related facial VAEs show recognizable Doppler ultrasound patterns, and the identification of these patterns may improve localization of vascular occlusion and support ultrasound-guided hyaluronidase administration, potentially enabling more targeted delivery with lower doses.

Для цитирования: Sigrist Rosa M S, Gonzalez Claudia, Schelke Leonie, Wortsman Ximena, Desyatnikova Stella, Cavallieri Fernanda A, Chammas Maria Cristina. Doppler Ultrasound Findings in Filler-Related Facial Vascular Adverse Events: An International Multicenter Study.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16111587.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.