OBJECTIVE

To assess the diagnostic accuracy of [99m Tc]pertechnetate scintigraphy in pediatric patients with suspected Meckel's diverticulum (MD).

METHODS

A retrospective study was conducted on 94 pediatric patients who presented with symptoms suggestive of MD and underwent [99m Tc]pertechnetate scintigraphy at Henan Provincial People's Hospital between September 2012 and August 2024. For patients with high clinical suspicion and equivocal scintigraphy results, Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) or repeat scintigraphy was conducted. Hemoglobin levels were measured in all patients, and their correlation with MD was analyzed. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall diagnostic accuracy were calculated by comparing scintigraphic results with surgical and histopathological findings.

RESULTS

Among the 94 patients, 20 (21.3%) had positive [99m Tc]pertechnetate scintigraphy, all confirmed as true positives through laparoscopic resection and histopathological examination. Of the 74 patients with negative scintigraphy results, 6 were found to be false negatives based on surgical findings, and 68 were confirmed as true negatives. Therefore, the sensitivity, specificity, PPV, and NPV were 76.9% (20/26), 100.0% (68/68), 100.0% (20/20), and 91.9% (68/74), respectively. The overall diagnostic accuracy was 93.6% (88/94). SPECT/CT was utilized in three cases, enhancing diagnostic precision in patients with equivocal planar imaging results. Repeat scintigraphy was performed in three patients with high clinical suspicion and negative initial scans, resulting in one additional positive diagnosis. MD patients exhibited significantly lower hemoglobin levels compared to non-MD patients (88.69 ± 20.39 g/L vs. 107.24 ± 29.28 g/L; p = 0.0009), with hemoglobin showing moderate predictive value (AUC = 0.70; 95% CI: 0.60-0.81).

CONCLUSION

[99m Tc]pertechnetate scintigraphy is a highly specific and accurate tool for diagnosing MD in pediatric patients. However, due to the potential for false negatives, additional SPECT/CT imaging or repeat scintigraphy may be warranted in cases with high clinical suspicion.

Для цитирования: Li Bo, Gao Jian, Ding Xintao, Li Xiali, Yu Yue, Long Ye, Wang Xiaohui, Wu Xinyu, Gao Yongju. Diagnostic accuracy of [99m Tc]pertechnetate scintigraphy in pediatric patients with suspected Meckel's diverticulum: a 12-year, monocentric, retrospective experience.. Frontiers in medicine. 2025. DOI: 10.3389/fmed.2025.1585313.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.