DOI 10.1016/j.ophtha.2006.10.051

Медицинская библиотека · Ophthalmology · 2007

Computed tomography in the diagnosis of occult open-globe injuries.

Arey Mark L, Mootha V Vinod, Whittemore Anthony R, Chason David P, Blomquist Preston H

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine the radiographic signs present on computed tomography (CT) most suggestive of occult open-globe injury.

DESIGN

Retrospective chart review.

PARTICIPANTS

Forty-eight eyes (of 46 patients), 34 of which were found to have an occult open-globe injury on surgical exploration.

METHODS

A retrospective chart review of all eyes of patients 18 years or older undergoing surgical exploration to rule out occult open-globe injury after CT examination at Parkland Memorial Hospital between October, 1998, and September, 2003, was conducted. Patients with obvious corneal or corneoscleral lacerations or with uveal prolapse were excluded. The CT films were obtained and independently reviewed by 3 masked observers (2 neuroradiologists and 1 ophthalmologist).

MAIN OUTCOME MEASURES: Presence of occult open-globe injury with respect to radiographic globe and orbital findings.

RESULTS

The sensitivity of CT for determining occult open-globe injury varied from 56% to 68% between the observers, specificity ranged from 79% to 100%, positive predictive value ranged from 86% to 100%, and negative predictive value ranged from 42% to 50%. Open-globe injuries averaged more CT findings per patient compared with intact globes (P = 0.047). Statistically significant CT findings for occult open-globe injury included any change in globe contour (P = 0.001), obvious volume loss (P = 0.003), an absent or dislocated lens (P = 0.048), vitreous hemorrhage (P = 0.003), and retinal detachment (P = 0.044). Additionally, moderate to severe change in globe contour, obvious volume loss, total vitreous hemorrhage, and absence of lens were seen only in eyes with occult rupture.

CONCLUSIONS

Although CT scanning may provide valuable information in patients in whom an occult open-globe injury is suspected, its sensitivity and specificity are inadequate to be relied on fully, and such patients generally should be taken to the operating room for formal surgical evaluation. Significant changes in globe contour or obvious volume loss are strong predictors of globe rupture, and any vitreous hemorrhage should be a concern for occult injury.

Для цитирования: Arey Mark L, Mootha V Vinod, Whittemore Anthony R, Chason David P, Blomquist Preston H. Computed tomography in the diagnosis of occult open-globe injuries.. Ophthalmology. 2007. DOI: 10.1016/j.ophtha.2006.10.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.