A new method for localizing the landmark of axillary vein and its application.

Wang Xiaxia, Zhang Yongtao, Zhang Yingying

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Axillary vein puncture is a popular puncture site for pacemaker implantation. However, due to the lacking of body surface markers, the current puncture method is too complicated and affect the popularization and application of axillary vein puncture. Here, we performed a new body surface landmark to make the blind axillary vein puncture simple and easy.

METHODS

The study population included 30 patients referred for pacemaker implantation using axillary vein puncture. Digital subtraction angiography (DSA) was used to determine the direction and the surface landmarks of the axillary vein. Medial cusp of thoracic triangle and the coracoid process were directly touched with fingers. The puncture point was about 1 cm below the coracoid, and the needle tip pointed to the medial cusp of thoracic triangle with the angle of 30-60°.

RESULTS

There was little variation in distribution of axillary vein. The body surface landmark of the junction of the axillary vein and the subclavian vein is on the medial cusp of thoracic triangle. In these 30 patients, blind axillary vein puncture was successful obtained in all patients. There was no pneumothorax and inadvertent arterial puncture. The pacemaker lead wire was placed smoothly. Moreover, the pacemaker pocket was ideally positioned when cut along the puncture point.

CONCLUSIONS

Blind axillary vein access using the body surface landmark of the thoracic triangle is an effective method for pacemaker implantation and can obvious avoid the complications usually observed with the traditional subclavian vein approach.

Для цитирования: Wang Xiaxia, Zhang Yongtao, Zhang Yingying. A new method for localizing the landmark of axillary vein and its application.. Indian pacing and electrophysiology journal. 2022. DOI: 10.1016/j.ipej.2022.07.009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.