BACKGROUND

The aim of this study was to evaluate a newly developed PCR-based reverse blot hybridization assay (PCR-REBA), REBA Sepsis-ID (M&D, Wonju, Korea), to rapidly detect the presence of bacteremia and antimicrobial resistance gene in blood culture samples.

METHODS

One thousand four hundred consecutive blood culture samples from patients with a delta neutrophil index greater than 2.7% were selected from March to July in 2013. Three hundred positive and 1,100 negative for bacterial growth in blood culture bottles samples were tested by conventional and real-time PCR-REBA, respectively.

RESULTS

The overall agreement between the conventional identification test and the REBA Sepsis-ID test was 95.3% (286/300). Agreement for gram-positive bacteria, gram-negative bacteria, fungi, and polymicrobials was 94.5% (190/201), 97.3% (71/73), 100% (14/14), and 91.7% (11/12), respectively. The detection rate of the mecA gene from methicillin-resistant Staphylococcus isolates was 97.8% (90/92). The vanA gene was detected in one blood culture sample from which vancomycin-resistant Enterococcus was isolated. When the cycle threshold for real-time PCR was defined as 30.0, 2.4% (26/1,100) of negative blood culture samples tested positive by real-time PCR.

CONCLUSIONS

The REBA Sepsis-ID test is capable of simultaneously and quickly detecting both causative agents and antimicrobial resistance genes, such as mecA and van, in blood culture positive samples.

Для цитирования: Park Soon Deok, Lee Gyusang, Wang Hye-Young, Park Min, Kim Sunghyun, Kim Hyunjung, Kim Jungho, Kim Young Keun, Kim Hyo Youl, Lee Hyeyoung, Uh Young, Kim Jong Bae. Evaluation of PCR-reverse blot hybridization assay, REBA Sepsis-ID test, for simultaneous identification of bacterial pathogens and mecA and van genes from blood culture bottles.. Annals of laboratory medicine. 2014. DOI: 10.3343/alm.2014.34.6.446.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.