Validity and Reliability of the French Olfactory Disorders Questionnaire-10.

Lechien Jérôme R, Vaira Luigi A, Lamoulen Lea, Sowerby Leigh, Radulesco Thomas, Michel Justin, Boscolo-Rizzo Paolo, Salzano Giovanni, Barillari Maria R, Saibene Alberto M, Cammaroto Giovanni, Chiesa-Estomba Carlos M, Iannella Giannicola, Van der Poel Nicolien, Sagandykova Kalamkas, Saussez Sven, Carsuzaa Florent, Mayo-Yanez Miguel, Bhargava Eishaan Kamta, Maniaci Antonino, Briganti Giovanni

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

ImportanceMost French Olfactory Questionnaires are time consuming, which may affect the patient participation.ObjectiveTo validate a short French version of the Olfactory Disorders Questionnaire (Fr-ODQ).DesignProspective controlled study.SettingMulticenter study.ParticipantsPatients with long-lasting olfactory dysfunction (OD) treated with platelet-rich plasma into the olfactory clefts and asymptomatic subjects.InterventionDevelopment and validation of a short ODQ.Main OutcomesIndividuals completed the full Fr-ODQ. The Threshold, Discrimination, and Identification (TDI) test was performed in OD patients. A combined statistical analysis was performed to determine the most informative items of the Fr-ODQ to develop a shorter version. The internal consistency was determined with Cronbach's alpha. The reliability and external validity were evaluated through a test-retest approach and by correlating with the Fr-ODQ. Both the minimal clinically important difference (MCID) and the threshold of the short ODQ version were determined.ResultsA total of 263 patients (173 [65.8%] females) and 129 controls (92 [71.3%] females) completed the evaluations. The mean age of patients was 51.2 ± 15.3 years. The mean duration of OD was 42.4 ± 54.3 months. The biostatistical models selected 10 essential items composing the Fr-ODQ-10. The baseline Fr-ODQ-10 was significantly correlated with the TDI (rs = 0.228; P = .001) and the Fr-ODQ (rs = 0.875; P = .001), demonstrating high external validity. Fr-ODQ-10 was significantly lower in controls compared to OD patients (P = .001), highlighting high internal validity. The internal consistency was good (α = .796). The external consistency was adequate, with significant correlations between the test-retest Fr-ODQ-10. The Fr-ODQ-10 significantly decreased from baseline to 4 months post-treatment. A Fr-ODQ-10 score >7.5 was considered abnormal (sensitivity: 84.8%, specificity: 84.2%). The MCID of Fr-ODQ-10 was established at >3.Conclusion and RelevanceThe Fr-ODQ-10 is a valid and reliable clinical instrument, demonstrating correlation with the psychophysical olfactory assessment.

Для цитирования: Lechien Jérôme R, Vaira Luigi A, Lamoulen Lea, Sowerby Leigh, Radulesco Thomas, Michel Justin, Boscolo-Rizzo Paolo, Salzano Giovanni, Barillari Maria R, Saibene Alberto M, Cammaroto Giovanni, Chiesa-Estomba Carlos M, Iannella Giannicola, Van der Poel Nicolien, Sagandykova Kalamkas, Saussez Sven, Carsuzaa Florent, Mayo-Yanez Miguel, Bhargava Eishaan Kamta, Maniaci Antonino, Briganti Giovanni. Validity and Reliability of the French Olfactory Disorders Questionnaire-10.. Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale. 2025. DOI: 10.1177/19160216251387622.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.