DOI 10.1097/mat.0000000000002388
Ventricular Assist Device Implantation in a Patient Congenitally Corrected Transposition of the Great Arteries With I, D, D.
Аннотация
Congenitally corrected transposition of the great arteries (ccTGA) is a rare congenital heart anomaly that often leads to systemic heart failure, necessitating mechanical circulatory support or transplantation. We report a case of a 54 year old male diagnosed with dextrocardia and ccTGA (I, D, D), who had been suffering from congestive heart failure for over 7 years. Despite receiving intensive treatment, his condition deteriorated. Preoperative evaluation revealed significant systemic right ventricular dysfunction with severe valvular regurgitation and pulmonary hypertension. The surgical approach included tricuspid and aortic bioprosthetic valve replacement, mitral valve annuloplasty, and right thoracic ventricular assist device (VAD) implantation. The patient recovered well postoperatively and was discharged on postoperative day 39 with New York Heart Association (NYHA) class I. This case demonstrates the feasibility of using VAD in right heart ccTGA as a bridge to transplantation or destination therapy, emphasizing the importance of meticulous preoperative planning and intraoperative management for successful outcomes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.