MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mpa.0000000000002207

Медицинская библиотека · Pancreas · 2022

Value of Dual-Energy Computed Tomography for Detecting Small Pancreatic Ductal Adenocarcinoma.

Fujisaki Yosuke, Fukukura Yoshihiko, Kumagae Yuichi, Ejima Fumitaka, Yamagishi Ryoji, Nakamura Shinya, Kamizono Junki, Kurahara Hiroshi, Hashimoto Shinichi, Yoshiura Takashi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of the study is to evaluate the usefulness of virtual monoenergetic imaging (VMI) generated from dual-energy computed tomography (DECT) in detecting small pancreatic ductal adenocarcinomas (PDACs).

METHODS

This study included 82 patients pathologically diagnosed with small PDAC (≤30 mm) and 20 without pancreatic tumors who underwent triple-phase contrast-enhanced DECT. To assess diagnostic performance for small PDAC detection via a receiver operating characteristic analysis, 3 observers reviewed 2 image sets (conventional computed tomography [CT] set and combined image set [conventional CT + 40-keV VMI from DECT]). The tumor-to-pancreas contrast-to-noise ratio was compared between conventional CT and 40-keV VMI from DECT.

RESULTS

The area under the receiver operating characteristic curve of the 3 observers were 0.97, 0.96, and 0.97 in conventional CT set and 0.99, 0.99, and 0.99 in combined image set (P = 0.017-0.028), respectively. The combined image set yielded a better sensitivity than the conventional CT set (P = 0.001-0.023), without a loss of specificity (all P > 0.999). The tumor-to-pancreas contrast-to-noise ratios of 40-keV VMI from DECT were approximately threefold higher than those of conventional CT at all phases.

CONCLUSIONS

The addition of 40-keV VMI from DECT to conventional CT had better sensitivity for detecting small PDACs without compromising specificity.

Для цитирования: Fujisaki Yosuke, Fukukura Yoshihiko, Kumagae Yuichi, Ejima Fumitaka, Yamagishi Ryoji, Nakamura Shinya, Kamizono Junki, Kurahara Hiroshi, Hashimoto Shinichi, Yoshiura Takashi. Value of Dual-Energy Computed Tomography for Detecting Small Pancreatic Ductal Adenocarcinoma.. Pancreas. 2022. DOI: 10.1097/mpa.0000000000002207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.