Establishment and verification of the dose-effect curve of dicentric chromosomes by semi-automatic analysis of human peripheral blood irradiated by X-ray in vitro.

Gao Yu, Han Lin, Li Jie, Lu Xue, Wang Ping, Du Shasha, Zhang Yunfei, Cai Tian-Jing, Liu Qing-Jie, Lyu Yumin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To establish and validate a dose-response curve for dicentric chromosomes (DC) induced by X-rays in human peripheral blood in vitro using semi-automated scoring.

METHODS

Peripheral blood samples were collected from three healthy individuals and exposed to X-ray doses of 0, 0.25, 0.5, 0.75, 1, 2, 3, 4, and 5 Gy at a dose rate of 1.158 Gy/min. Dicentric chromosomes in metaphase were scored both full- and semi-automatically, and a dose-response curve was generated with CABAS software based on dicentric yields. Dose estimations were then performed for 12 biodosimetry standard samples and one sample from a patient with X-ray-induced skin injury.

RESULTS

Dicentric yields increased with X-ray doses from 0 to 5 Gy (r = 0.943, P < 0.01). The dose-response association followed a linear-quadratic model: Y = 0.0002 (± 0.0001) + 0.0379 (± 0.0032) × D + 0.0253 (± 0.0014) × D2 (R2 = 0.998, P < 0.01), where Y represents dicentric yields and D is the dose. The estimated dose for 12 validation samples aligned closely with actual doses. The estimated whole-body average absorbed dose for the patient was 0.73 Gy, with observed DC over-dispersion suggesting partial body exposure. By using the Dolphin model, this dose was refined to 2.22 Gy and estimated irradiated body volume was 35.94%, consistent with clinical diagnosis.

CONCLUSIONS

The dose-response curve developed using semi-automated scoring offer a reliable and efficient approach for dose estimation and clinical diagnosis in nuclear radiation emergencies. It could also support retrospective biodosimetry of partial-body, non-uniform radiation exposure.

Для цитирования: Gao Yu, Han Lin, Li Jie, Lu Xue, Wang Ping, Du Shasha, Zhang Yunfei, Cai Tian-Jing, Liu Qing-Jie, Lyu Yumin. Establishment and verification of the dose-effect curve of dicentric chromosomes by semi-automatic analysis of human peripheral blood irradiated by X-ray in vitro.. International journal of radiation biology. 2025. DOI: 10.1080/09553002.2025.2494549.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.