DOI 10.1007/s11547-025-02161-1
Added value of diffusion-weighted imaging in detecting breast cancer missed by artificial intelligence-based mammography.
Аннотация
OBJECTIVE
To evaluate breast cancers missed by artificial intelligence-based computer-aided diagnosis (AI-CAD) in women newly diagnosed with breast cancer, identify factors associated with these missed cases, and assess the potential diagnostic value of standalone diffusion-weighted imaging (DWI) in detecting cancers overlooked by AI-CAD.
MATERIALS AND
METHODS
This retrospective study included 414 women (mean age, 55.3 years) with pathologically confirmed breast cancer who underwent preoperative mammography, MRI with DWI, and surgery. Cancers were classified as AI-detected if the lesion had an abnormality score greater than 10 and was correctly localized by AI-CAD; otherwise, they were categorized as AI-missed. Clinicopathologic and imaging features were compared between groups. Two radiologists independently reviewed DWI of AI-missed cancers and assigned malignancy confidence scores using a 6-point Likert-type scale (≥3 considered positive). Interobserver agreement and diagnostic performance were analyzed.
RESULTS
AI-CAD missed 127 of 414 breast cancers (30.7%). Multivariate regression analysis identified dense breasts (adjusted OR = 1.619; p = 0.049) and tumor size ≤ 2 cm (adjusted OR = 4.698; p < 0.001) as independent predictors of AI-missed cancer. Standalone DWI detected 83.5% and 79.5% of AI-missed cancers for Radiologists 1 and 2, respectively, with substantial agreement (κ = 0.61). DWI was effective in detecting mammographically occult or >1 cm tumors, but sensitivity declined for subcentimeter lesions.
CONCLUSION
Standalone DWI detects the majority of breast cancers missed by AI-CAD, supporting its potential role as a triage adjunct in AI-based screening, particularly for dense breasts and mammographically occult lesions. However, the retrospective, cancer-only design limits generalizability, highlighting the need for prospective multicenter screening trials for validation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.