DOI 10.3109/08820538.2014.962164
Two-Year Follow-Up of Artisan Iris-Supported Phakic Anterior Chamber Intraocular Lens for Correction of High Myopia.
Аннотация
PURPOSE: To evaluate the results of Artisan iris-supported phakic anterior chamber intraocular lens (pIOL) implantation in patients with high myopia.
METHODS
Medical records of patients who underwent Artisan pIOL implantation for surgical correction of myopia were retrospectively reviewed. Only patients with at least a two- year follow-up were included. Spherical equivalent of manifest refractive error (SE), uncorrected visual acuity (UDVA), distance corrected visual acuity (CDVA), and endothelial cell density (ECD) were analyzed at six months, one year, and two years after surgery.
RESULTS
Sixty-two eyes of 42 patients were included in the study. All patients had a minimum anterior chamber depth of 3.0 mm from the endothelium. At two years, 68% of the patients were within ±0.50 D. Mean ECD was 2723 ± 311 cells/mm(2) preoperatively and 2630 ± 291 cells/mm(2) at six months postoperatively (3.4% loss, p = 0.001). ECD loss from six months postoperatively to two years postoperatively was not statistically significantly different. In three eyes (4.8%) of two patients, a temporary, steroid-induced increase in intraocular pressure (IOP) was detected.
CONCLUSION
Artisan pIOL implantation is a safe and highly effective procedure for surgical correction of high myopia. ECD loss stabilizes in the early postoperative period.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.