MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00192-013-2140-9

Медицинская библиотека · International urogynecology journal · 2013

Obturator neuropathy: an adverse outcome of a trans-obturator vaginal mesh to repair pelvic organ prolapse.

Van Ba Ornella Lam, Wagner Laurent, de Tayrac Renaud

Клинический случайСтатьяПеревод в очереди

Аннотация

We report a case of obturator neuropathy induced by trans-obturator vaginal mesh surgery for symptomatic cystocele. Initial electromyography excluded genito-femoral and pudendal nerve deficiency. Typical clinical arguments for severe obturator neuropathy at physical examination led to vaginal revision surgery with hemi-resection of the mesh to the ischio-pubic branch. This fully relieved obturator-induced pain and reversed adductor muscle motor deficiency.

Для цитирования: Van Ba Ornella Lam, Wagner Laurent, de Tayrac Renaud. Obturator neuropathy: an adverse outcome of a trans-obturator vaginal mesh to repair pelvic organ prolapse.. International urogynecology journal. 2013. DOI: 10.1007/s00192-013-2140-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.