Аннотация

BACKGROUND

A variety of screening methods are currently used worldwide in order to decrease the risk of transfusion-transmitted sepsis and improve the safety of PCs.

METHODS/MATERIALS: PCs inoculated with five different transfusion-relevant species of bacteria at concentrations of 1, 10, and 100 colony-forming units (CFU)ml(-1) were stored at 22°C for 7 days. Flow cytometry (FACS), BacT/Alert automated culturing, and a quantitative real-time PCR (Q-PCR) were then used to detect the presence of bacteria in samples prepared from these PCs.

RESULTS

At the initial spiking concentrations of 1, 10, and 100 CFU ml(-1), Q-PCR detected all five bacterial species tested. Screening with the BacT/Alert culture-based system allowed bacterial detection (inoculated on day 0) within a mean time of 15.13 h for all three spiking concentrations. Using FACS, positive signals were obtained for all three concentrations of Escherichia coli and Bacillus cereus on day 1 and for initial spiking concentrations of Pseudomonas aeruginosa and Staphylococcus aureus of 1 CFU ml(-1) on day 2. For Staphylococcus epidermidis, detection of an initial inoculum of 1 CFU ml(-1) was possible only beginning on day 6.

CONCLUSION

This study shows that under standard laboratory conditions the sensitivity of FACS in the detection of bacterial contamination of PCs was lower than that of either the BacT/Alert automated culturing method or Q-PCR.

Для цитирования: GuoHui Bian, Chunhui Yang, Miao He, Hong Wang, Jiaxin Liu, Ye Cao, Hong Yang, Zhong Liu, Wuping Li. Three different bacterial detection systems for platelet concentrates under inter-laboratory conditions.. Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis. 2013. DOI: 10.1016/j.transci.2013.07.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.