DOI 10.1016/j.tripleo.2008.11.015
Chemical composition, radiopacity, and biocompatibility of Portland cement with bismuth oxide.
Аннотация
OBJECTIVE
This study compared the chemical constitution, radiopacity, and biocompatibility of Portland cement containing bismuth oxide (experimental cement) with those of Portland cement and mineral trioxide aggregate (MTA).
STUDY
DESIGN
The chemical constitution of materials was determined by scanning electron microscopy and energy-dispersive X-ray analysis. The radiopacity of the materials was determined using the ISO/6876 method. The biocompatibility of the materials was tested by MTT assay and tissue reaction.
RESULTS
The constitution of all materials was similar. However, the Portland cement and experimental cement were more irregular and had a larger particle size than MTA. The radiopacity of the experimental cement was similar to MTA. The MTT assay revealed MTA to have slightly higher cell viability than the other materials. However, there were no statistically significant differences between the materials, with the exception of MTA at 24 h. There was no significant difference in the tissue reaction between the experimental groups.
CONCLUSIONS
These results suggest that the experimental cement may be used as a substitute for MTA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.