Implementation of a Self-Measured Blood Pressure Pilot Program in an Academic Internal Medicine Practice.
Аннотация
BACKGROUND
Self-measured blood pressure (SMBP) monitoring is a proposed strategy to improve hypertension control, but few studies compare SMBP with automated office blood pressure (AOBP) measurements over time. Moreover, little is known about reimbursement for these services.
METHODS
We describe a quality improvement initiative in our academic internal medicine practice. Patients received validated home blood pressure (BP) devices and were instructed to check their BP twice daily for 7 days each month. Devices transmitted readings seamlessly via a smartphone application that averaged weekly readings. Clinicians reviewed the data and adjusted therapy if indicated. We tracked changes in SMBP, AOBP, antihypertensive medications, and reimbursement.
RESULTS
Among 140 patients referred (mean age 57.6 years, 57.1% women, 25.7% Black), 59 completed the program. Over 6 months, the mean self-measured systolic BP decreased by 5.8 mm Hg (95% CI: -8.2 to -3.5) and the mean diastolic BP decreased by 2.8 mm Hg (95% CI: -4.2 to -1.4) and the number with BP <130/<80 mm Hg increased by 22 percentage points (P = 0.007). However, unattended AOBP showed no change in either systolic (change: 0.1 mm Hg; P = 0.98) or diastolic (change: -0.6 mm Hg; P = 0.64) readings. Reimbursement was variable and ranged from no payment to a maximum payment of $51; when paid, the average payment was $13.81.
CONCLUSIONS
In this program, SMBP decreased over time while AOBP remained similar. Reimbursement, when received, was modest. Future work should evaluate whether using SMBP as a therapeutic target reduces cardiovascular events.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.