DOI 10.1038/s41372-025-02262-9
Cardiac biomarkers predict low right ventricle performance in neonatal encephalopathy.
Аннотация
OBJECTIVE
Study the association between cardiac biomarkers and echocardiography parameters of ventricular performance in neonates with neonatal encephalopathy (NE).
METHODS
Prospective observational study (2016-2021) of neonates undergoing therapeutic hypothermia (TH). Neonates with brain injury had repeated echocardiography and biomarkers measurements on day of life (DOL) 2, 3, 4, and 10. Pearson correlation and generalized linear mixed effect models were used to account for repeated measurements. Receiver operating characteristic curves were constructed to assess sensitivity/specificity.
RESULTS
56 neonates had 128 measurements. Creatine Kinase (CK) and cardiac troponin-I (CTn-I) were associated with right ventricular (RV) function. A CK of 1961 U/L and a CTn-I of 91 ng/L identified low Tricuspid Annular Plane Systolic Excursion (<7 mm) with sensitivities of 93% and 79%, and specificities of 55% and 74%, respectively.
CONCLUSIONS
Elevated CK and CTn-I were associated with decreased RV performance. Trending these markers can be used to suspect altered RV function and may flag optimal timing for evaluation(s) by echocardiography during TH.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.