NIR Spectroscopy as an Online PAT Tool for a Narrow Therapeutic Index Drug: Toward a Platform Approach Across Lab and Pilot Scales for Development of a Powder Blending Monitoring Method and Endpoint Determination.

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Talwar Sameer, Pawar Pallavi, Wu Huiquan, Sowrirajan Koushik, Wu Suyang, Igne Benoît, Friedman Richard, Muzzio Fernando J, Drennen James K

Аннотация

An online near-infrared (NIR) spectroscopy platform system for real-time powder blending monitoring and blend endpoint determination was tested for a phenytoin sodium formulation. The study utilized robust experimental design and multiple sensors to investigate multivariate data acquisition, model development, and model scale-up from lab to manufacturing. The impact of the selection of various blend endpoint algorithms on predicted blend endpoint (i.e., mixing time) was explored. Spectral data collected at two process scales using two NIR spectrometers was incorporated in a single (global) calibration model. Unique endpoints were obtained with different algorithms based on standard deviation, average, and distributions of concentration prediction for major components of the formulation. Control over phenytoin sodium's distribution was considered critical due to its narrow therapeutic index nature. It was found that algorithms sensitive to deviation from target concentration offered the simplest interpretation and consistent trends. In contrast, algorithms sensitive to global homogeneity of active and excipients yielded the longest mixing time to achieve blending endpoint. However, they were potentially more sensitive to subtle uniformity variations. Qualitative algorithms using principal component analysis (PCA) of spectral data yielded the prediction of shortest mixing time for blending endpoint. The hybrid approach of combining NIR data from different scales presents several advantages. It enables simplifying the chemometrics model building process and reduces the cost of model building compared to the approach of using data solely from commercial scale. Success of such a hybrid approach depends on the spectroscopic variability captured at different scales and their relative contributions in the final NIR model.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты