Microperimetric evaluation for different methods of epiretinal membrane surgery.

Nam Seung Wan, Byun Zeeyoon, Ham Don-Il, Kong Mingui

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the anatomic and functional outcomes using microperimetry for the surgical methods for idiopathic epiretinal membranes (ERM).

METHODS

This retrospective study included 41 eyes from 41 patients. All patients underwent combined epiretinal membrane and cataract surgery. Best-corrected visual acuity (BCVA), optical coherence tomography, and microperimetry were performed before and 6 months and 1 year after surgery. The patients were divided into 3 groups; "ERM removal only without indocyanine green (ICG) staining", "ERM and internal limiting membrane (ILM) removal without ICG staining", and "ERM and ILM removal with ICG staining".

RESULTS

Preoperatively, the ages, BCVAs, central macular thickness (CMT), and mean retinal sensitivities of central 6° (MRSs) of the groups were not significantly different (p > 0.05). Postoperatively, the MRSs of the "ERM removal only without ICG staining" and "ERM and ILM removal without ICG staining" groups were not significantly different (p > 0.05). The MRSs of the "ERM and ILM removal without ICG staining" and "ERM and ILM removal with ICG staining" groups were not significantly different (p > 0.05). However, the MRSs of the "ERM and ILM removal with ICG staining" group significantly reduced than "ERM removal only without ICG staining" group (p < 0.05).

CONCLUSION

This retrospective study found reduced retinal sensitivity in ERM and ILM removal with ICG staining group compared to ERM removal only without ICG staining. Further studies with larger sample sizes are required.

Другие публикации по теме

Retrospective StudiesX-Linked Intellectual DisabilityIndocyanine GreenCataract Extraction
Для цитирования: Nam Seung Wan, Byun Zeeyoon, Ham Don-Il, Kong Mingui. Microperimetric evaluation for different methods of epiretinal membrane surgery.. BMC ophthalmology. 2023. DOI: 10.1186/s12886-023-03056-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.