MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003246-200009000-00014

Медицинская библиотека · Critical care medicine · 2000

High adenosine plasma concentration as a prognostic index for outcome in patients with septic shock.

Martin C, Leone M, Viviand X, Ayem M L, Guieu R

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Sepsis and septic shock are a common cause of mortality in critically ill patients. Many substances have been implicated in the pathophysiology of these syndromes. We postulated that adenosine may be implicated in the sepsis- or septic shock-induced blood pressure failure. Indeed, this nucleoside is a strong endogenous vasodilating agent released by endothelial cells and myocytes under circumstances of metabolic stress, such as during critical illness.

DESIGN

A prospective, comparative observational study.

SETTING

The adult intensive care unit of a tertiary care university hospital.

PATIENTS: We measured adenosine plasma concentration (APC) in patients with severe sepsis (n = 11), in patients with septic shock (n = 14), in patients with hemorrhagic traumatic shock (n = 14), and in 12 healthy volunteers. APC was evaluated every 12 hrs over 3 days.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

At study entry, we found that APC was higher in patients with septic shock (mean +/- so = 8.4 +/-3.5 micromol/L) than in patients with hemorrhagic traumatic shock (1.1 +/- 0.6 micromol/L) and controls (0.8 +/- 0.3 micromol/L). Intermediate values (3.9 +/- 1.9 micromol/L) were found in patients with severe sepsis. APC in patients with traumatic shock did not differ from controls. In the course of the hospitalization, for both sepsis and septic shock patients, APC decreased significantly but remained higher than controls 72 hrs after entry into the study. In the septic shock group, APC was significantly higher in the nonsurvivor group (n = 6) than in the survivor group (n = 8), whatever the time of sample collection and assay.

CONCLUSIONS

High adenosine plasma concentrations are found in patients with septic shock but not during traumatic shock, or in healthy volunteers. Intermediate values of circulating adenosine are found in patients with severe sepsis. APC may be a prognostic index for outcome in septic patients, with much higher values being found in nonsurvivors.

Для цитирования: Martin C, Leone M, Viviand X, Ayem M L, Guieu R. High adenosine plasma concentration as a prognostic index for outcome in patients with septic shock.. Critical care medicine. 2000. DOI: 10.1097/00003246-200009000-00014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.