MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-018-3009-7

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2018

Long-term survival of the cemented Müller CDH stem: a minimum follow-up of 10 years.

Salentiny Yves, Zwicky Lukas, Ochsner Peter E, Clauss Martin

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Total hip arthroplasty in patients with altered anatomy of the hip and femur, such as in congenital dysplasia of the hip, is challenging and often requires specially designed stems. Müller straight stems have shown excellent long-term results; however, long-term data on the analogous cemented Müller CDH stem are still missing. The aim of this study was to analyze long-term survival, identify potential risk factors for aseptic loosening, and analyze radiological outcome of the cemented Müller CDH stems.

MATERIALS AND

METHODS

Between 01/1985 and 06/2005, 95 Müller CDH stems (Zimmer, Winterthur, Switzerland) made up of 3 different materials were cemented using 2 different bone cements: 38 of stainless steel/high-viscosity cement, 31 of a cobalt-chrome-based alloy (CoCr)/low-viscosity cement, and 26 of a titanium-based alloy (Ti)/low-viscosity cement. All patients had a prospective clinical and radiological follow-up according to the standards of our institution. The cumulative incidence for revision of the stem was calculated using a competing risk model. To identify demographic and implant-related risk factors for aseptic loosening of the stem, a multivariate regression model for competing risks was performed.

RESULTS

The cumulative risk of revision at 15 years was 12.5% (95% CI 6.6-20.5%) for aseptic loosening of the stem as endpoint, with marked differences for the various stem materials used: stainless steel 2.7% (0.2-12.3%), CoCr 12.9% (4.0-27.3%), and Ti 24.5% (9.6-43.1%). Regression modeling revealed that Ti stems in combination with low-viscosity cement (HR 10.2) and implantation with an axis deviation greater than 3° (HR 3.8) are risk factors for aseptic loosening.

CONCLUSIONS

Long-term survival of the cemented Müller CDH stem is comparable to other Müller-type straight stems and uncemented implants. Similar to the original Ti Müller straight stem, the Ti Müller CDH stem also showed an increased risk for aseptic loosening and should, therefore, no longer be used.

Для цитирования: Salentiny Yves, Zwicky Lukas, Ochsner Peter E, Clauss Martin. Long-term survival of the cemented Müller CDH stem: a minimum follow-up of 10 years.. Archives of orthopaedic and trauma surgery. 2018. DOI: 10.1007/s00402-018-3009-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.