BACKGROUND

Surface roughness (SR) of dental components is significant because it impacts the surface area of the contact surface, which in turn affects corrosion behavior and biological compatibility. Orthodontic archwires (OA) with SR can affect the coefficient of friction, which in turn affects how effectively sliding biomechanics work and how the orthodontic appliance works efficiently.

AIM: The objectives of the present investigation were to examine the SR of five distinct kinds of OA using an atomic force microscope (AFM) and to assess the merits of using AFM to analyze orthodontic materials.

METHODS

For this investigation, there were five distinct orthodontic archwires with rectangular cross-sectional geometry. There were assigned different categories: Category 1: SmartArch wires (Ormco) (n=20), Category 2: Damon wires (Ormco) (n=20), Category 3: heat-activated nickel-titanium (HANT) wires (G&H Orthodontics) (n=20), Category 4: nickel-titanium (NiTi) wires (G&H Orthodontics) (n=20), Category 5: stainless steel (SS) wires (Ormco) (n=20). Each wire category's 20 samples were selected. Ten samples from each category had 5 mm of wire clipped from the finish point of the archwires. These were observed using the AFM in natural lighting. Using a cyanoacrylate glue that dries quickly, the samples were fastened to a metal holder. Ten randomly chosen patches of the surface, each measuring 15 × 15 µm, were taken from every sample and examined (N = 500).

RESULTS

The mean values of roughness average (Ra) in category 1, category 2, category 3, category 4 and category 5 were 23.08 ± 17.66, 26.78 ± 5.65, 26.66 ± 3.89, 9.71 ± 0.29 and 11.29 ± 2.12 respectively. The values of Ra representing SR were greatest in category 3 (HANT wires) followed by category 2 (Damon wires) while values of SR were minimum in category 4 (NiTi wires) and category 5 (stainless steel wires). The findings had statistical significance also.

CONCLUSION

The SR of stainless steel wire was discovered to be less than that of the other wires. The SR may have an impact on the efficiency of sliding mechanics as well as the appeal and corrosion resistance of orthodontic components.

Для цитирования: Ashique Abdulhameed Syed, S Brijesh, Sunny Jose, Goswami Dwijesh S, Abraham Nevin, Asha Ambroise Marie. Comparison of Surface Roughness of Different Orthodontic Archwires: Atomic Force Microscopic Study.. Cureus. 2024. DOI: 10.7759/cureus.51516.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.