MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-022-03156-5

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023

Extracardiac findings with increased perfusion during clinical O-15-H2O PET/CT myocardial perfusion imaging: A case series.

Jochumsen Mads Ryø, Overgaard David Lyse, Vendelbo Mikkel Holm, Madsen Michael Alle, Tolbod Lars Poulsen, Gormsen Lars Christian, Barkholt Trine Ørhøj

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Coincidental extracardiac findings with increased perfusion were reported during myocardial perfusion imaging (MPI) with various retention radiotracers. Clinical parametric O-15-H2O PET MPI yielding quantitative measures of myocardial blood flow (MBF) was recently implemented at our facility. We aim to explore whether similar extracardiac findings are observed using O-15-H2O.

METHODS AND

RESULTS

All patients (2963) were scanned with O-15-H2O PET MPI according to international guidelines and extracardiac findings were collected. In contrast to parametric O-15-H2O MBF images, extracardiac perfusion was assessed using summed images. Biopsy histopathology and other imaging modalities served as reference standards. Various malignant lesions with increased perfusion were detected, including lymphomas, large-celled neuroendocrine tumour, breast, and lung cancer plus metastases from colonic and renal cell carcinomas. Furthermore, inflammatory and hyperplastic benign conditions with increased perfusion were observed: rib fractures, gynecomastia, atelectasis, sarcoidosis, pneumonia, chronic lung inflammation and fibrosis, benign lung nodule, chronic diffuse lung infiltrates, pleural plaques and COVID-19 infiltrates.

CONCLUSIONS

Malignant and benign extracardiac coincidental findings with increased perfusion are readily visible and frequently seen on O-15-H2O PET MPI. We recommend evaluating the summed O-15-H2O PET images in addition to the low-dose CT attenuation images.

Для цитирования: Jochumsen Mads Ryø, Overgaard David Lyse, Vendelbo Mikkel Holm, Madsen Michael Alle, Tolbod Lars Poulsen, Gormsen Lars Christian, Barkholt Trine Ørhøj. Extracardiac findings with increased perfusion during clinical O-15-H2O PET/CT myocardial perfusion imaging: A case series.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2023. DOI: 10.1007/s12350-022-03156-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.