MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjcr/ytad434

Медицинская библиотека · European heart journal. Case reports · 2023

Transcatheter mitral valve replacement to treat severe calcified rheumatic native mitral stenosis: role of three-dimensional printing-a case report.

Zhai Meng-En, Mao Yu, Liu Yang, Yang Jian

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Rheumatic heart disease is a major disease that seriously affects human health and survival worldwide. Rheumatic mitral stenosis often has relatively complex pathological changes, and its progression leads to various manifestations of mitral valve dysfunction and adverse clinical events.

CASE SUMMARY: We present a 60-year-old patient who developed chest tightness, shortness of breath, and bilateral lower limb oedema in 2018 (New York Heart Association functional class III). Systolic and diastolic murmurs could be heard in the mitral auscultation area. In December 2021, the patient was admitted to the hospital with stroke. Thereafter, transthoracic echocardiography and computed tomography were performed, and the progress of rheumatic mitral stenosis was recorded. Due to the patient's high surgical risk, a patient-specific three-dimensional printed model was used to observe anatomical structures and simulate main procedures, and the surgeons finally chose to perform transcatheter mitral valve replacement. The balloon-expandable bioprothesis was released from the right femoral artery to treat the rheumatic mitral stenosis. The patient remained asymptomatic at the 6-month follow-up.

DISCUSSION: For patients with rheumatic mitral stenosis with high surgical risk, it is feasible to conduct transcatheter mitral valve replacement under the guidance of three-dimensional printing.

Для цитирования: Zhai Meng-En, Mao Yu, Liu Yang, Yang Jian. Transcatheter mitral valve replacement to treat severe calcified rheumatic native mitral stenosis: role of three-dimensional printing-a case report.. European heart journal. Case reports. 2023. DOI: 10.1093/ehjcr/ytad434.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.