MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-026-01916-0

Медицинская библиотека · Journal of imaging informatics in medicine · 2026

Automated Detection of Patent Ductus Arteriosus in Pediatric Patients Using Doppler Ultrasonography Videos Based on a Transformer Model.

Hong Wenjing, Xu Xiaodong, Yuan Jiajun, Wu Lanping, Wang Xike, Kong Linghui, Zhang Xuehua, Chen Lijun, Liu Yiman, Wang Aiqing, Li Sheng, Shen Rong, Zhu Junxue, Wu Tianze, Dong Bing, Wang Hansong, Zhao Liebin, Liu Xiaoqing, Zhang Yuqi

СтатьяПеревод в очереди

Аннотация

Patent ductus arteriosus (PDA) is a common congenital heart defect that requires timely and accurate detection to guide clinical management. Although deep learning has shown considerable promise in medical imaging, its application to echocardiographic video analysis remains challenging due to complex temporal dynamics and heterogeneous imaging conditions. TimeSformer, a Transformer-based architecture for temporal video modeling, is well suited for capturing long-range dependencies in echocardiographic sequences. In this study, we propose a novel two-stage artificial intelligence framework for automated PDA detection using Doppler echocardiography videos. In the first stage, parasternal short-axis (PSA) views are automatically identified and extracted from raw ultrasound videos. In the second stage, temporal features are analyzed to perform video-level diagnostic classification. To ensure robustness and generalizability, the proposed framework was developed and validated using a diverse multi-center dataset comprising examinations from four medical centers and four different ultrasound devices. The proposed method achieves high accuracy in view classification and effectively discriminates between PDA-positive and PDA-negative cases, yielding an area under the receiver operating characteristic curve (AUC) of 0.95. These results demonstrate the effectiveness of TimeSformer for echocardiographic sequence interpretation. Furthermore, the multi-center and multi-device validation highlights the adaptability of the framework, supporting its potential role as an AI-assisted diagnostic tool to enhance clinical workflows and patient outcomes in congenital heart disease.

Для цитирования: Hong Wenjing, Xu Xiaodong, Yuan Jiajun, Wu Lanping, Wang Xike, Kong Linghui, Zhang Xuehua, Chen Lijun, Liu Yiman, Wang Aiqing, Li Sheng, Shen Rong, Zhu Junxue, Wu Tianze, Dong Bing, Wang Hansong, Zhao Liebin, Liu Xiaoqing, Zhang Yuqi. Automated Detection of Patent Ductus Arteriosus in Pediatric Patients Using Doppler Ultrasonography Videos Based on a Transformer Model.. Journal of imaging informatics in medicine. 2026. DOI: 10.1007/s10278-026-01916-0.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.