MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjcr/ytag366

Медицинская библиотека · European heart journal. Case reports · 2026

Non-contrast trans-catheter aortic valve implantation using Evolut self-expanding platform: a wire backup technique case report.

Chatterjee Krishnarpan, Ali Mohamed, Alkhalil Mohammad

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Concomitant aortic stenosis and chronic kidney disease (CKD) represent management challenges. Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with symptomatic severe aortic stenosis but requires the use of contrast media, particularly in patients undergoing self-expanding platform implantation. Therefore, patients with CKD remain at an increased risk of developing worsening renal impairment post TAVI.

CASE SUMMARY: Herein, we present a 62-year-old male patient who was admitted with progressive dyspnoea. His transthoracic echocardiogram revealed severe aortic stenosis and impaired left ventricular systolic function (an estimated ejection fraction of 35%). He has a background of porcelain aorta and CKD. Despite low-dose contrast CT, the patient's renal function significantly deteriorated. He was successfully treated with trans-catheter aortic valve implantation using a self-expanding valve (Evolut) without the need for contrast media. The procedure was guided by catheter positioning in the non-coronary cusp and the wire back-up technique in the left coronary cusp.

CONCLUSION

This case demonstrated the feasibility of implanting a self-expanding trans-catheter heart valve using the Evolut platform without the need for the use of contrast media in a patient at high risk of worsening renal impairment. The current approach requires good procedural planning and additional vascular access and should be used only in highly selected cases.

Для цитирования: Chatterjee Krishnarpan, Ali Mohamed, Alkhalil Mohammad. Non-contrast trans-catheter aortic valve implantation using Evolut self-expanding platform: a wire backup technique case report.. European heart journal. Case reports. 2026. DOI: 10.1093/ehjcr/ytag366.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.