MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0031126

Медицинская библиотека · PloS one · 2012

Highly sensitive detection of Staphylococcus aureus directly from patient blood.

Banada Padmapriya P, Chakravorty Soumitesh, Shah Darshini, Burday Michele, Mazzella Fermina M, Alland David

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Rapid detection of bloodstream infections (BSIs) can be lifesaving. We investigated the sample processing and assay parameters necessary for highly-sensitive detection of bloodstream bacteria, using Staphylococcus aureus as a model pathogen and an automated fluidic sample processing-polymerase chain reaction (PCR) platform as a model diagnostic system.

METHODOLOGY/PRINCIPAL FINDINGS: We compared a short 128 bp amplicon hemi-nested PCR and a relatively shorter 79 bp amplicon nested PCR targeting the S. aureus nuc and sodA genes, respectively. The sodA nested assay showed an enhanced limit of detection (LOD) of 5 genomic copies per reaction or 10 colony forming units (CFU) per ml blood over 50 copies per reaction or 50 CFU/ml for the nuc assay. To establish optimal extraction protocols, we investigated the relative abundance of the bacteria in different components of the blood (white blood cells (WBCs), plasma or whole blood), using the above assays. The blood samples were obtained from the patients who were culture positive for S. aureus. Whole blood resulted in maximum PCR positives with sodA assay (90% positive) as opposed to cell-associated bacteria (in WBCs) (71% samples positive) or free bacterial DNA in plasma (62.5% samples positive). Both the assays were further tested for direct detection of S. aureus in patient whole blood samples that were contemporaneous culture positive. S. aureus was detected in 40/45 of culture-positive patients (sensitivity 89%, 95% CI 0.75-0.96) and 0/59 negative controls with the sodA assay (specificity 100%, 95% CI 0.92-1).

CONCLUSIONS

We have demonstrated a highly sensitive two-hour assay for detection of sepsis causing bacteria like S. aureus directly in 1 ml of whole blood, without the need for blood culture.

Для цитирования: Banada Padmapriya P, Chakravorty Soumitesh, Shah Darshini, Burday Michele, Mazzella Fermina M, Alland David. Highly sensitive detection of Staphylococcus aureus directly from patient blood.. PloS one. 2012. DOI: 10.1371/journal.pone.0031126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.