DOI 10.1016/j.healun.2023.05.006
Infections following left ventricular assist device implantation and 1-year health-related quality of life.
Аннотация
BACKGROUND
Left ventricular assist device (LVAD) implantation leads to substantial and sustained improvement in health-related quality of life (HRQOL) among patients. Infection following device implantation remains an important and frequent complication and adversely affects patient-reported HRQOL.
METHODS
Patients in The Society of Thoracic Surgeons' Interagency Registry for Mechanically Assisted Circulatory Support receiving a primary LVAD between April 2012 to October 2016 were included. The primary exposure was one-year post-implant infection, characterized by: (1) any infection; (2) total number of infections and (3) type (LVAD-specific, LVAD-related, non-LVAD). The association between infection and the primary composite adverse outcome (defined as EuroQoL Visual Analog Scale< 65, too sick to complete the survey, or death at 1-year) was estimated using inverse probability weighting and Cox regression.
RESULTS
The study cohort included 11,618 patients from 161 medical centers with 4,768 (41.0%) patients developing an infection, and 2,282 (19.6%) patients having> 1 infection during the follow up period. The adjusted odds ratio for the primary composite adverse outcome was 1.22 (95% CI, 1.19-1.24, p < 0.001) for each additional infection. Each additional infection was associated with a 3.49% greater probability of the primary composite outcome and was associated with worse performance across multiple dimensions of HRQOL as assessed by the EQ-5D for patients who survived to 1 year.
CONCLUSIONS
For patients undergoing LVAD implantation, each additional infection within the first post-implantation year was associated with an incremental negative effect on survival free of impaired HRQOL.