MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.123.030333

Медицинская библиотека · Journal of the American Heart Association · 2023

Short-Term Effects of Different Transcatheter Edge-to-Edge Devices on Mitral Valve Geometry.

Rosch Sebastian, Kösser Luise, Besler Christian, Kister Tobias, Kresoja Karl-Patrik, Kiefer Philipp, Marin-Cuartas Mateo, Meineri Massimiliano, Leontyev Sergey, Abdel-Wahab Mohamed, Borger Michael A, Thiele Holger, Ender Jörg, Lurz Philipp, Noack Thilo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Background Short-term effects on mitral valve (MV) anatomy after transcatheter edge-to-edge repair using the PASCAL system remain unknown. Precise quantification might allow for an advanced analysis of predictors for mean transmitral gradients. Methods and Results Consecutive patients undergoing transcatheter edge-to-edge repair for secondary mitral regurgitation using PASCAL or MitraClip systems were included. Quantification of short-term MV changes throughout the cardiac cycle was performed using peri-interventional 3-dimensional MV images. Predictors for mean transmitral gradients were identified in univariable and multivariable regression analysis. Long-term results were described during 1-year follow-up. A total of 100 patients undergoing transcatheter edge-to-edge repair using PASCAL (n=50) or MitraClip systems (n=50) were included. Significant reductions of anterior-posterior diameter, annular circumference, and area throughout the cardiac cycle were found in both cohorts (P<0.05 for all). Anatomic MV orifice area remained larger in the PASCAL cohort in mid (2.8±1.0 versus 2.4±0.9 cm2; P=0.049) and late diastole (2.7±1.1 versus 2.2±0.8 cm2; P=0.036) compared with the MitraClip cohort. Besides a device-specific profile of independent predictor of mean transmitral gradients, reduction of middiastolic anatomic MV orifice area was identified as an independent predictor in both the PASCAL (β=-0.410; P=0.001) and MitraClip cohorts (β=-0.318; P=0.028). At follow-up, reduction of mitral regurgitation grade to mild or less was more durable in the PASCAL cohort (90% versus 72%; P=0.035). Conclusions PASCAL and MitraClip showed comparable short-term effects on MV geometry. However, PASCAL might better preserve MV function and demonstrated more durable mitral regurgitation reduction during follow-up. Identification of independent predictors for mean transmitral gradients might potentially help to guide device selection in the future.

Для цитирования: Rosch Sebastian, Kösser Luise, Besler Christian, Kister Tobias, Kresoja Karl-Patrik, Kiefer Philipp, Marin-Cuartas Mateo, Meineri Massimiliano, Leontyev Sergey, Abdel-Wahab Mohamed, Borger Michael A, Thiele Holger, Ender Jörg, Lurz Philipp, Noack Thilo. Short-Term Effects of Different Transcatheter Edge-to-Edge Devices on Mitral Valve Geometry.. Journal of the American Heart Association. 2023. DOI: 10.1161/jaha.123.030333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.