MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00006565-199710000-00001

Медицинская библиотека · Pediatric emergency care · 1997

Effect of fever on capillary refill time.

Gorelick M H, Shaw K N, Murphy K O, Baker M D

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To assess the effect of fever on capillary refill time in children.

DESIGN

Prospective cohort study.

SETTING

Tertiary care children's hospital emergency department (ED).

PARTICIPANTS

Convenience sample of 234 children age one month to five years presenting to the ED with a complaint of vomiting, diarrhea, or poor oral fluid intake.

INTERVENTION: None.

MEASUREMENTS: Before any therapy, capillary refill was measured according to a standard protocol. Rectal temperature was measured in children less than three years old, oral temperature in older children. Fluid deficit was calculated as the percentage difference between initial weight and stable weight following treatment.

MAIN

RESULTS

Among the 80 children with dehydration, defined as a deficit of > or = 5% of body weight, mean capillary refill was 2.0 +/- 1.0 seconds, versus 1.3 +/- 0.5 seconds in the well hydrated group (P < 0.001). Within each group, mean capillary refill time for febrile patients (temperature > or = 38.3 degrees C) was essentially the same as in those without fever. Using a two-second upper limit of normal, prolonged capillary refill had a sensitivity of 0.44 and specificity of 0.94 for diagnosing dehydration; the diagnostic performance did not differ when stratified by presence or absence of fever.

CONCLUSIONS

Presence of fever does not have a clinically important effect on capillary refill time in children.

Для цитирования: Gorelick M H, Shaw K N, Murphy K O, Baker M D. Effect of fever on capillary refill time.. Pediatric emergency care. 1997. DOI: 10.1097/00006565-199710000-00001.