Intralenticular metal foreign body: case report.

Medina Flavio Mac Cord, Pierre Filho Paulo de Tarso Ponte, Lupinacci Alvaro Pedroso de Carvalho, Costa Dacio Carvalho, Torigoe Andréa Mara Simões

Клинический случайСтатьяПеревод в очереди

Аннотация

Intralenticular foreign bodies comprise about 5% to 10% of all intraocular foreign bodies and can result in serious complications. The management depends on some factors like size, location, material type and the risk of infection. We present a patient with an intralenticular metal foreign body in the left eye that, following initial treatment with topical steroid and antibiotic, underwent lens aspiration with removal of the intralenticular foreign body and insertion of a posterior chamber intraocular lens with good visual outcome.