MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0954411912470243

Медицинская библиотека · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2012

Volume rendering of three-dimensional fluoroscopic images for percutaneous scaphoid fixation: an in vitro study.

Smith Erin J, Al-Sanawi Hisham, Gammon Braden, Pichora David R, Ellis Randy E

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Percutaneous fixation of scaphoid fractures offers potential advantages to cast treatment but can be difficult to perform with conventional two-dimensional imaging. This study aimed to evaluate the use of a novel navigation technique using volume-rendered images derived from intraoperative cone-beam computed tomography imaging, without the need for typical patient-based registration. Randomized in vitro trials in which a guidewire was inserted into a scaphoid model were conducted to compare volumetric navigation to conventional fluoroscopic C-arm (n = 24). Central wire placement, surface breach, procedure time, drilling attempts, and radiation exposure were compared between groups. Compared to conventional percutaneous insertion, navigation achieved equal or significantly better placement of the guidewire with fewer drilling attempts and less radiation exposure. On average, navigation took 74 s longer to perform than the conventional method, which was statistically significant but clinically irrelevant. This evaluation suggests that the technology is promising and may have many clinical benefits including improved fixation placement, fewer complications, and less radiation exposure. The intraoperative workflow is more efficient and eliminates the need for preoperative computed tomography, image segmentation, and patient-based registration typical of traditional navigated procedures.

Для цитирования: Smith Erin J, Al-Sanawi Hisham, Gammon Braden, Pichora David R, Ellis Randy E. Volume rendering of three-dimensional fluoroscopic images for percutaneous scaphoid fixation: an in vitro study.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2012. DOI: 10.1177/0954411912470243.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.