MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10096-011-1310-2

Медицинская библиотека · European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2011

Factors influencing the clinical outcome of methicillin-resistant Staphylococcus aureus bacteraemia.

Albur M S, Bowker K, Weir I, MacGowan A

СтатьяПеревод в очереди

Аннотация

Methicillin-resistant Staphylococcus aureus (MRSA) bacteraemia is associated with high mortality due to a combination of host, pathogen and therapy related factors. This was a retrospective exploratory study to evaluate host, pathogen and therapy related factors influencing the clinical outcome of MRSA bacteraemia in a UK teaching hospital setting. Of the 38 consecutive episodes of MRSA bacteraemia over a 1-year period, 16 of 38 (40%) patients died at 1 month and 21/38 (55%) died at 6 months. Univariate analysis revealed age (p < 0.006), mean serum vancomycin level (p < 0.035), agr group I (p < 0.036) and set4-var2_11 gene (p < 0.036) at 1 month; and age (p < 0.004) and set4-var2_11 gene (p < 0.002) at 6 months as significant factors. However, there was no association between first trough vancomycin concentration and outcome at 1 month. Multivariate survival analysis from time of admission showed, for each one year increase in age, a patient is 1.121 (95% CI 1.006-1.250, p < 0.007) times more likely to die at any particular point in time, and patients with a mean serum vancomycin level of <10 mg/L, the odds ratio of adverse outcome is 16.129 (95% CI 2.398-111.111) compared to patients with a mean serum level >10 mg/L. A variety of host, pathogen, and therapy related factors influence the clinical outcome of MRSA bacteraemia.

Для цитирования: Albur M S, Bowker K, Weir I, MacGowan A. Factors influencing the clinical outcome of methicillin-resistant Staphylococcus aureus bacteraemia.. European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology. 2011. DOI: 10.1007/s10096-011-1310-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.