OBJECTIVE To evaluate the effect of 2 bronchoalveolar lavage (BAL) sampling techniques and the use of N-butylscopolammonium bromide (NBB) on the quantity and quality of BAL fluid (BALF) samples obtained from horses with the summer pasture endophenotype of equine asthma. ANIMALS 8 horses with the summer pasture endophenotype of equine asthma. PROCEDURES BAL was performed bilaterally (right and left lung sites) with a flexible videoendoscope passed through the left or right nasal passage. During lavage of the first lung site, a BALF sample was collected by means of either gentle syringe aspiration or mechanical suction with a pressure-regulated wall-mounted suction pump. The endoscope was then maneuvered into the contralateral lung site, and lavage was performed with the alternate fluid retrieval technique. For each horse, BAL was performed bilaterally once with and once without premedication with NBB (21-day interval). The BALF samples retrieved were evaluated for volume, total cell count, differential cell count, RBC count, and total protein concentration. RESULTS Use of syringe aspiration significantly increased total BALF volume (mean volume increase, 40 mL [approx 7.5% yield]) and decreased total RBC count (mean decrease, 142 cells/μL), compared with use of mechanical suction. The BALF nucleated cell count and differential cell count did not differ between BAL procedures. Use of NBB had no effect on BALF retrieval. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that retrieval of BALF by syringe aspiration may increase yield and reduce barotrauma in horses at increased risk of bronchoconstriction and bronchiolar collapse. Further studies to determine the usefulness of NBB and other bronchodilators during BAL procedures in horses are warranted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты