MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2026.112744

Медицинская библиотека · European journal of radiology · 2026

Transfemoral vs. through-and-through wire technique for iliac branch device implantation - single-center retrospective study.

Sotir Anna, Fuchs Lukas, Klopf Johannes, El-Kilany Lina, Kölbel Tilo, Neumayer Christoph, Eilenberg Wolf, Wolf Florian

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To report the outcome of a wire-stabilized steerable sheath (SS group) approach for internal iliac artery (IIA) branch catheterization using contralateral transfemoral access and to compare its outcome to through-and-through wire technique (TnT group) for iliac branch device (IBD) procedures.

METHODS

A retrospective analysis of 51 consecutive patients treated for aortoiliac or isolated IIA aneurysm from January 2020 to July 2023 was undertaken. Primary endpoints were radiation exposure, volume of contrast agent (CA), operation time and incidence of intraoperative target vessel (TV) complications. Type IB/C and IIIA/C endoleak, incomplete/complete thrombotic occlusion of TV, re-intervention rates at early (< 30 days after IBD), short (30 days - 6 months) and intermediate (> 6 months) follow-up were secondary endpoints.

RESULTS

12 patients in SS and 39 patients in TnT were identified. History of previous endovascular aneurysm repair (EVAR) was more prevalent in SS, p = 0.001. Non-significantly lower operation time (median, 204 vs. 262 min, p = 0.081) could be found in SS vs. TnT. Dose-area product (median, 301 vs. 361 Gy x cm2), CA (median, 148 vs. 190 mL) were non-significantly lower in SS vs. TnT. TV complications were observed in TnT only (7.7%). Incomplete/complete thrombotic occlusion of IIA branch was less frequently observed in SS vs. TnT at 3 follow-up phases (1 vs. 4 case, 1 vs. 5 case, respectively).

CONCLUSIONS

SS approach might be considered as a viable and technically safe option for patients with/without prior history of aortoiliac repair.

Для цитирования: Sotir Anna, Fuchs Lukas, Klopf Johannes, El-Kilany Lina, Kölbel Tilo, Neumayer Christoph, Eilenberg Wolf, Wolf Florian. Transfemoral vs. through-and-through wire technique for iliac branch device implantation - single-center retrospective study.. European journal of radiology. 2026. DOI: 10.1016/j.ejrad.2026.112744.

Предметные рубрики MeSH