The use of somatosensory evoked potentials for detection of neuropraxia during shoulder arthroscopy.

Pitman M I, Nainzadeh N, Ergas E, Springer S

Клинический случайСтатьяПеревод в очереди

Аннотация

With the increase in the use of shoulder arthroscopy in the past decade, there has been an increased awareness of complications. Reports of the occurrence of transient neuropraxia indicate an incidence of 10%-30%. The recording of somatosensory evoked potentials (SEP) for the study and functional monitoring of the sensory pathway is well accepted as a reproducible method of monitoring peripheral nerve and spinal cord function during surgery. SEPs were recorded during shoulder arthroscopy in 20 patients to monitor the musculocutaneous nerve, ulnar nerve, and either the median or radial nerve. In all 20 cases, abnormal SEPs of the musculocutaneous nerve were demonstrated. In 16 cases, this was produced upon initial joint distention, and in 15 cases, by traction; in 11, by longitudinal traction of greater than or equal to 12 lb, and in six by perpendicular traction of greater than or equal to 7 lb. In 10 patients, there were varying combinations of median, ulnar, and radial nerve involvement. There were two cases of clinical neuropraxia in this series. One resolved in 24 h and one in 48 h. The conclusion is that there is a real potential for neurologic damage during shoulder arthroscopy and that the musculocutaneous nerve is the most vulnerable. Factors responsible include joint distention, excessive traction, and extravasation of fluid. The use of SEPs provides a reliable means for monitoring the neurologic status of the extremity during shoulder arthroscopy.

Для цитирования: Pitman M I, Nainzadeh N, Ergas E, Springer S. The use of somatosensory evoked potentials for detection of neuropraxia during shoulder arthroscopy.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 1988. DOI: 10.1016/s0749-8063(88)80039-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.