BACKGROUND

Healthcare contributes substantially to greenhouse gas emissions (GHG), and anaesthesia is recognised as a high-impact sector. Evidence comparing the carbon footprint of anaesthetic techniques remains limited, particularly in Europe. We quantified carbon dioxide equivalent (CO2e) emissions from inhalation anaesthesia with low-flow sevoflurane, TIVA and spinal anaesthesia during operative hysteroscopy.

METHODS

We performed a prospective GHG-focused life cycle assessment of consecutive patients undergoing operative hysteroscopy in a French university hospital. For each case, we recorded gases, drugs, medical devices, electricity consumption, and their respective costs. Carbon footprints were calculated by Assistance Publique - Hôpitaux de Paris Carebone® platform and expressed in CO2e.

RESULTS

We included 123 participants: 72 underwent inhalation anaesthesia, 22 underwent TIVA, and 29 underwent spinal anaesthesia. Total carbon emissions differed significantly across techniques: median emissions were 10.8 kgCO2e [9.1-12.6] for inhalation anaesthesia, 6.6 kgCO2e [6.4-6.9] for TIVA and 5.5 kgCO2e [5.3-6.2] for spinal anaesthesia (P<0.001). Volatile anaesthetics were the main contributors for inhalation anaesthesia, pharmaceuticals for TIVA and single-use devices for spinal anaesthesia. Electricity consumption was similar across groups.

CONCLUSIONS

Spinal anaesthesia demonstrated the lowest carbon footprint. TIVA represented the lowest-carbon option for general anaesthesia techniques, whereas inhalation anaesthesia yielded the highest CO2e emissions despite low-flow delivery. These findings highlight the mitigation potential of anaesthetic choice even in low-complexity procedures.

Для цитирования: Lechani Lina, Verdonk Franck, Daigné Daisy, Maire Mathilde, Tan Davuth, Cambriel Amélie, Kapandji Natacha, Pardo Emmanuel, Taconet Clémentine. Assessing the carbon footprint of inhalation anaesthesia, total intravenous anaesthesia, and spinal anaesthesia for a single surgical procedure: a prospective observational study.. British journal of anaesthesia. 2026. DOI: 10.1016/j.bja.2026.06.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.