MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1364/boe.425411

Медицинская библиотека · Biomedical optics express · 2021

High-speed and widefield handheld swept-source OCT angiography with a VCSEL light source.

Ni Shuibin, Wei Xiang, Ng Ringo, Ostmo Susan, Chiang Michael F, Huang David, Jia Yali, Campbell J Peter, Jian Yifan

СтатьяПеревод в очереди

Аннотация

Optical coherence tomography (OCT) and OCT angiography (OCTA) enable noninvasive structural and angiographic imaging of the eye. Portable handheld OCT/OCTA systems are required for imaging patients in the supine position. Examples include infants in the neonatal intensive care unit (NICU) and operating room (OR). The speed of image acquisition plays a pivotal role in acquiring high-quality OCT/OCTA images, particularly with the handheld system, since both the operator hand tremor and subject motion can cause significant motion artifacts. In addition, having a large field of view and the ability of real-time data visualization are critical elements in rapid disease screening, reducing imaging time, and detecting peripheral retinal pathologies. The arrangement of optical components is less flexible in the handheld system due to the limitation of size and weight. In this paper, we introduce a 400-kHz, 55-degree field of view handheld OCT/OCTA system that has overcome many technical challenges as a portable OCT system as well as a high-speed OCTA system. We demonstrate imaging premature infants with retinopathy of prematurity (ROP) in the NICU, a patient with incontinentia pigmenti (IP), and a patient with X-linked retinoschisis (XLRS) in the OR using our handheld OCT system. Our design may have the potential for improving the diagnosis of retinal diseases and help provide a practical guideline for designing a flexible and portable OCT system.

Для цитирования: Ni Shuibin, Wei Xiang, Ng Ringo, Ostmo Susan, Chiang Michael F, Huang David, Jia Yali, Campbell J Peter, Jian Yifan. High-speed and widefield handheld swept-source OCT angiography with a VCSEL light source.. Biomedical optics express. 2021. DOI: 10.1364/boe.425411.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.